5.08 mm pluggable pulls free of the header
A pluggable terminal block splits the joint in two: a fixed header on the panel side and a plug the wiring rides in. Servicing then means pulling the plug instead of loosening twenty screws. The pitch is 5.08 mm, a spacing that keeps the socket walls thick enough for repeated mating. Wire lands in the plug with a screw or spring clamp depending on the variant, and the whole connection comes apart as one piece.
Fifteen amps typical and 2500 V of headroom
The plug is rated 15.0 A typical at 300 V AC typical, with a 2500 V AC typical withstanding test across adjacent circuits. Contact resistance is 20 mΩ max, insulation resistance 100 MΩ min, and the window is -40 °C to +105 °C typical. At 15 A the plug contact and the clamp do the work, so a properly seated wire matters more than the last newton of screw torque.
The mating half and the service story
Specify the plug and the header as a pair and the service story writes itself: mark the plug, keep a spare wired the same way, and a failed module swaps in minutes. Send the pole count and the drawing and the mating pair gets quoted from the same file. Sample pairs in small counts go out free for a fit check before the release quantity.